Analysis of Environmental Noise Levels around a Shopping Centre Using Smartphone-Based Acoustic Measurement: A Case Study of Duta Mall Palangka Raya

Authors

  • Norhalidah Universitas Muhammadiyah Palangkaraya Author

Keywords:

Environmental noise, Shopping centre, Smartphone, LAeq, Duta Mall Palangka Raya

Abstract

This study analysed environmental noise around Duta Mall Palangka Raya and its compliance with the Indonesian standard for trade and service areas. In a descriptive quantitative field study, a calibrated smartphone sound level meter on a tripod at about 1.5 m recorded 10-minute Lmin, LAeq, and Lmax at the mall's right and left sides in the morning, midday, afternoon, and evening of one weekday, following SNI 8427:2017. LAeq ranged 66.9–75.8 dB(A), with energy averages of 70.2 dB(A) on the right side and 73.5 dB(A) on the left side. Three of eight measurements exceeded the 70 dB(A) limit of KEP-48/MENLH/11/1996: the right side at midday (72.7 dB(A)) and the left side in the afternoon (75.8 dB(A)) and evening (75.6 dB(A)). Lmax of 87.0–91.3 dB(A) indicated frequent impulsive events. Measurements covered only two points on one weekday; smartphone results require validation against a standard sound level meter.

Published

13-11-2026

How to Cite

Analysis of Environmental Noise Levels around a Shopping Centre Using Smartphone-Based Acoustic Measurement: A Case Study of Duta Mall Palangka Raya. (2026). Jurnal Lingkungan Nusantara, 3(1), 35-42. https://journal.jantoscv.com/index.php/jln/article/view/100

Similar Articles

1-10 of 18